Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CALIBRATION

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0CALVAL0 (FORWARD_CALIBRATION_)CALDIR

CALDIR=FORWARD_CALIBRATION_

Description

Calibration Value Register

Fields

CALVAL

If enabled, the calibration counter counts up to this value. The maximum value is 131, 072 corresponding to about 36.4 hours. Calibration is disabled if CALVAL = 0.

CALDIR

Calibration direction

0 (FORWARD_CALIBRATION_): Forward calibration. When CALVAL is equal to the calibration counter, the RTC timers will jump by 2 seconds.

1 (BACKWARD_CALIBRATION): Backward calibration. When CALVAL is equal to the calibration counter, the RTC timers will stop incrementing for 1 second.

Links

()